Cable test program Shield-TS
 
      
      
    The Shield-TS series is characterized by the following features:
Supports network analyzers from different manufacturers and frequency ranges.  This is a control and evaluation software with graphical representation.
Fully automatic measuring system for the computer-controlled recording of the calibration and error correction data.
A modern, clear user interface helps with the handling of the? Program; Without technical knowledge, a rapid incorporation is possible.
Accurate and repeatable measurements of all relevant cable parameters. Optimized measuring speed to ensure a high test sample throughput.
Freely definable measuring sequences and settings avoid operator errors and improve the measuring sequence.
Integrated SQL database report designer for the design of customer-specific printouts; All measurement parameters can be printed out.
Capture, evaluate and document nearly all RF parameters for cables, assemblies and plugs / sockets. SHIELD-TS has been designed for detailed individual measurements on any DAs.
 
              
      
      
    | Measurements | Abbreviation | Handheld | VNA | 
| Transmission (Basis measure) | S-Param | ||
| Image Identuation | S21 | X | X | 
| Delay | S21 | X | X | 
| Skewr | S21 | X | |
| Coupling attenuation | S21 | X | |
| Screen efficiency | S21 | X | |
| Transfer impedance | S21 | X | |
| Transmission (Combinations) | |||
| Skew | S21 | X | A | 
| NEXT | S21 | X | A | 
| FEXT | S12 | X | A | 
| ACR | S21 | X | A | 
| ELFEXT | S12 | X | A | 
| ACR-F | S21 | X | A | 
| Power Sum ACR | S21 | X | A | 
| Power Sum NEXT | S21 | X | A | 
| Power Sum FEXT | S12 | X | A | 
| Power Sum ELFEXT | S12 | X | A | 
| Wave results | |||
| Wave impedance | S11 | X | |
| Wave impedance, real | S11 | X | |
| Wave impedance, imaginary | S11 | X | |
| Image attenuation const | S11, (O&S) | X | |
| Characteristic impedance | S21, C | X | |
| Impedance, short cables | S11, (O&S) | X | |
| Input results | |||
| Input impedance | S11 | X | X | 
| Fitted impedance | S11, S21 | X | |
| Return loss | S11, S22 | X | X | 
| SRL | S11 | X | |
| Constant | |||
| Phase constant | S11, 21 | X | |
| Resistance constant | S11, 21 | X | |
| Capacity constant | S11, 21 | X | |
| Inductivity constant | S11, 21 | X | |
| Mixed Mode | |||
| LCL | Sdc11 | X | |
| TCL | Scd11 | X | |
| LCLT | Sdc21 | X | |
| TCTL | Sdc12 | X | |
| EL LCTL | Sdc21 - Scc21 | X | |
| EL TCTL | Scd21 - Sdd21 | X | |
| Single Ended (16 types of measurement) | |||
| Sij11, Sij44, Sijxy | Scc11, Scc44 | X | |
| Special measurements | |||
| Zeven | Scc11, Scc22 | X | |
| Zodd | Scc11, Scc22 | X | |
| Zcom | Scc11, Scc22 | X | |
| Wiring | DC | X | X | 